Last previous edition approved in as D – Adopted as a joint ASTM/ IP standard in 2 For referenced ASTM standards, visit. Test Report of Foaming Characteristic (ASTM. D) and Air Release (ASTM D ). Test Report of Foaming Characteristic (ASTM. D) and Air Release. ASTM D Standard Test Method for Air Release Properties of Hydrocarbon Based Oils. standard by ASTM International, 10/01/ View all product.

Author: Bagrel JoJozil
Country: Hungary
Language: English (Spanish)
Genre: Photos
Published (Last): 4 February 2004
Pages: 427
PDF File Size: 12.32 Mb
ePub File Size: 14.26 Mb
ISBN: 769-3-79182-269-3
Downloads: 83562
Price: Free* [*Free Regsitration Required]
Uploader: Samubei

The apparatus adopts digital display temperature meter, control temperature with high accuracy. No other units of measurement are included in this standard. Build-in air heater, safe and fast Technical parameters 1. The component parts are described as follows: It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Interchanged parts may be used so long as the resultant test vessel conforms to the stated dimensions.

However, entrained air can cause sponginess and lack of sensitivity of the control of turbine and hydraulic systems. If the residence time in the reservoir is too short to allow the air bubbles to rise to the oil surface, a mixture of air and oil will circulate through the lubricating oil system. Pt Platinum resistor 7. NOTE 3—The application of thermal insulation to the pipework zstm the heated compressed air is recommended. Your comments will receive careful consideration at a meeting of the responsible technical committee,1 which you may attend.

Link to Active This link will always route to the current Active aetm of the standard.

Digital display temperature controller. Allow the sample to reach the test temperature. NOTE 11—The test may be run for a longer period of time by agreement between the laboratory and the customer.

  BZX84 C43 PDF

The significance of this test method has not been fully established.

Not exactly what you want? The axtm of this test method has not been fully established. Attach the sinker to the beam of the density balance by means of the platinum wire so that the bottom of the sinker is 10 6 2 mm from asym bottom of the test vessel. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

Digital air release properties tester, astm d3427 lubricating oil testing equipment

Box 70, Burlington, NJ Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Back pressure in excess of a gage pressure of 70 kPa 10 psi can be generated when the bath medium is pumped at the required rate; this can cause fracture of the glass or slippage of the hose connections.

Last previous edition approved in as D — Warning—The use of glass vessels with glass host?

This apparatus measures the time for the entrained air content to fall to the relatively low value of 0. However, entrained air can cause sponginess and lack of sensitivity of the control of turbine and hydraulic systems.

The significance of this test method has not been asttm established. This may result in an inability to maintain oil pressure particularly with centrifugal pumpsincomplete oil? It is used to test the ability of turbine, hydraulic, and gear oils to separate entrained air. Digital display temperature controller 4. NOTE 16—The precision statement was developed using 1. If the time is greater than 30 min, discontinue the test.

China kipps d3472 China weighing apparatus China melting point apparatus. Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. In d33427, use of a safety shield is recommended.

  2SD1556 DATASHEET PDF

A new interlaboratory test program is planned. NOTE 1—This test method was developed for mineral based oils. Warning—Compressed gas under high pressure. This can be obtained by an additional bath, or by using a separate steam or electric heat exchanger. A coil of copper tubing immersed in the d347 bath see 6. This is not what you are looking for? This test method was developed for hydrocarbon based oils. If you feel that your comments have not received a fair hearing you should v3427 your views known to the ASTM Committee on Standards, at the address shown below.

Originally approved in This test may not be suitable for ranking oils in applications where residence times are short and gas contents are high Features 1.

Air Release Value Apparatus ASTM D3427

Latest Products from This Supplier. Air from a cylinder or a nonpulsating pump may be used. How do you ship the products? China soxhlet apparatus China flash point apparatus China thermal conductivity apparatus.

The temperature of the air shall be measured by a thermometer located as close d347 possible to the testing vessel and meeting the speci?