IEC 61310-1 PDF

Purchase your copy of BS EN as a PDF download or hard International Relationships, EN (IEC ),IEC. Find the most up-to-date version of IEC at Engineering Back to Glossary Index. Specifies requirements for visual, acoustic and tactile methods of indicating safety-related information, at the.

Author: Akisho Mauramar
Country: Uruguay
Language: English (Spanish)
Genre: Technology
Published (Last): 22 March 2009
Pages: 374
PDF File Size: 4.44 Mb
ePub File Size: 15.77 Mb
ISBN: 388-4-24680-250-8
Downloads: 68318
Price: Free* [*Free Regsitration Required]
Uploader: Yozshugis

Active signals shall be provided to signal a hazard and to call persons to take a specific course of action. Switchgear, controlgear and fuses IEC All safety-related ice shall be so designed that their meaning is clearly and unambiguously evident to the operator. Where a product family or dedicated product standard exists, iev requirements take precedence. Codes shall be selected at an early stage iiec machinery design in accordance with this standard that is derived from IEC Requirements for visual, acoustic and tactile signals 1 Scope This part of IEC specifies requirements for visual, acoustic and tactile methods of indicating safety-related information, at the human-machine interface and to exposed persons.

At human-machine interfaces, warning and danger signals need to convey safety-related meanings for the safe use and monitoring of machinery for exposed persons and operators. To this end, such signals and their associated coding shall be applied consistently throughout the machinery. Customers who bought this 6131-1 also bought BS EN Requirements for visual, acoustic and tactile signals Status: IEC Kec Pause; interruption To identify the control or the indicator which stops operation intermittently and keeps the equipment in operating mode.

IEC A Normal run; normal speed To identify the switch or switch position by means ifc which a normal run for example, of tape is started in the indicated direction. The operation of the light source may be related to or independent of the actuator action [IEC NOTE 1 The meaning of this graphical symbol depends upon its orientation. For dated references, only the edition cited applies. Find Similar Items This product falls into the following categories.

  INFORME VALECH 2011 PDF

It is the constant aim of BSI to improve the quality of our products and services.

In many applications, the information is represented by a signal which is encoded by a distinct set of rules and the operator has then to interpret the signal according to these rules.

It specifies a system of colours, safety signs, markings and other warnings, intended for use in the indication of hazardous situations and ice hazards and for meeting certain emergencies.

IEC | In Compliance Magazine

NOTE In the orientation shown, the graphical symbol means “slow run, forward. Anzeigen, Kennzeichen und Bedienen.

Ied 3 β€” Zones of horizontal field of vision β€” 12 β€”EN NOTE 1 Tactile signals are conveyed when a part of the human body, for example, finger, hand, foot, is intentionally brought into contact with kec spatial surface of an actuator, for example, a push-button, a lever.

Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Worldwide Standards We can source any standard from anywhere in the world.

BS EN 61310-1:2008

Users of British Standards should make sure that they possess the latest amendments or editions. The faster, easier way to work with standards. Information shall be provided to enable instructions to be given to persons who may need to respond to such codes. Search all products by. Safety colours and contrast colours used in safety signs shall be in accordance with ISO Whilst their applications are mainly for electrotechnical purposes, the symbols shall be used for other types of actuators, for example, mechanical, hydraulic, using the same function.

Different types of coding such as colour, shape or time are used as appropriate to the demands of the task of the operator. NOTE 2 The measures taken should be determined from the jec assessment. For further discrimination and information, and especially to give additional emphasis, a flashing light should be used. Please download Chrome or Firefox or view our browser tips.

  ANTHONY GIDDENS SOCJOLOGIA PWN WARSZAWA 2007 PDF

You may find similar items within these categories by selecting from the choices below:. A version in any other language made by translation under the responsibility of a CENELEC member into ice own language and notified to the Central Secretariat has the same status as the official versions.

In the case of emergency stop actuators the use of contrast colours shall be in accordance with ISO Anforderungen an sichtbare, visuels, acoustiques et tactiles h rbare und tastbare Signale CEI The exposure can immediately or over a period of time result in harm [ISO You may experience issues viewing this site in Internet Explorer 9, 10 or Telegraphy, facsimile and data communication IEC Contact the Information Centre.

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Safety-related tactile signals shall be described on or near the actuating element and in the operating instructions. Requirements for visual, acoustic and tactile signalsICS Indication, marking and actuation.

NOTE To be used in association with the symbol Your basket is empty. Other requirements and other EC Directives may be applicable to the products falling within the scope of this standard. NOTE This means stopping either by electrical or mechanical disconnection. IEC B Alternative graphical representation. Where an operator has control or can intervene, the signal shall continue at least until the operator intervenes. NOTE 2 See also symbol Various BSI electronic information services are also available which give details on all its products and services.

In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.

Author: admin